4.   do not install a fuse in the 
neutral or ground circuit. A 
fuse in the neutral or ground 
circuit may result in an 
electrical shock hazard.
5.   do not ground the appliance 
to a gas supply pipe or hot 
water pipe.
6.  A grounded cold water pipe 
must have metal continuity to 
electrical ground and must not 
be interrupted by insulating 
materials. Any insulating 
materials must be jumped  
with a length of No. 4 copper 
wire securely clamped to bare 
metal at both ends.
Grounding Instructions (All Models)
This appliance must be electrically 
grounded.
With the range positioned directly in front of 
the cabinet cutout, feed the appliance conduit 
to the electrical junction box. Then, depending 
upon local codes, utilize one of the following 
techniques to connect the appliance to the 
electrical power supply:
A.  Connecting to a Four-wire Electrical 
System. (Recommended for All Models)
1.  Separate the green and white appliance 
wires.
2.  Connect the white appliance wire to the 
neutral (white) supply wire in the junction 
box.
3.  Connect the black appliance wire to the 
black (L1) power supply wire in the junction 
box.
4.  Connect the red appliance wire to the red 
(L2) power supply wire in the junction box.
5.  Connect the green appliance wire to the 
green house grounding wire in the junction 
box.
Door Opened
Range Top
23 1/2"
(597mm)
26 9/16"
(675mm)
Rear of Control
Panel/Oven Door
Max. depth
to oven door
handle with
door closed
30"
(762mm)
45 1/4"
(1149mm)
Overall dimensions (Preference Models)
Isometric View
Door Opened
Range Top
23 1/2"
(597mm)
25 5/16"
(643mm)
Rear of Control
Panel/Oven Door
Max. depth
to oven door
handle with
door closed
30"
(762mm)
45 1/4"
(1149mm)
Overall dimensions (MRES Model)
Isometric View
Installing the Anti-Tip Bracket
wARNING:
This appliance require an anti-
tip device. Before installing the 
range, you must locate and secure 
the anti-tip bracket to the floor.
When the range is slid into position in the 
cutout, the left rear leveling leg slides into this 
bracket to prevent the unit from tipping forward. 
The bracket location shown here will position the 
rear edge of the range top frame flush to the rear 
wall. From this position, the bracket allows for up 
to 5/8” (16mm) of forward movement of the range.
1 1/2”
(38mm)
24”
(610mm)
1”
(25mm)
11 3/8”
(289mm)
2 3/16”
(556mm)
Front face
of cabinet
19 7/16”
(494mm)
CL
Location of Anti-Tip Bracket
Top View
Removing the Oven door
wARNINGS:
1.  do not attempt to disengage 
the hinge catches with the 
door removed from the oven. 
The hinge springs could 
release causing personal 
injury.
2.  do not lift or carry the oven 
door by the door handle.
Open the door to its fully opened position. 
Rotate the catch over the retaining arm on each 
hinge. Lift the oven door to about a 30 degree 
angle from the horizontal position. Pull the door 
away from the oven while continuing to lift.
Removing the Oven door
Remove the kick Panel (All Models)
Remove the screw at each top corner of the 
kick panel. Lift up slightly on the panel and pull 
forward to remove
Electrical Connection
NOTE:
 
See the range data plate for 
electrical specifications. See 
page 1 for location.
wARNINGS:
1.   All of these range models 
must be connected to a 
grounded, metallic, permanent 
wiring system. Alternatively, a 
grounding conductor should 
be connected to the grounding 
terminal or lead on the 
appliance. 
3.   do not use an extension cord 
with this appliance. Such use 
may result in fire, electrical 
shock, or other personal 
injury.
Conduit from
appliance
Cable from
power supply
Wire nut
(4 places)
Junction
box
RED
RED
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
Connecting the appliance to a
four-wire power supply
(All Models)