2. Checks Before Installation
1) Remove the shipping carton, tape, and packing material.
2) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the 
fan blade moves freely.
3. Setup
1) Assemble 2 sets of legs using the legs, bolts, and nuts provided. See Fig. 11. 
2) Position 1 of the plates provided between a set of legs and the remote condenser unit, 
then secure the legs to the remote condenser unit with the bolts and nuts provided. 
Repeat on the other side with the remaining set of legs.
3) The bottom of each leg has a mounting hole. Secure the legs to the permanent site with 
4 bolts (not included).
 Fig. 11
Bolt with Split Lock 
Washer and Flat Washer
Nut
Plate
Leg
Bolt with Split Lock 
Washer and Flat Washer
Nut
4. Line Set Size and Refrigerant Charge
NOTICE
The icemaker, line set, and remote condenser unit must contain the same type 
of refrigerant. Mixing of refrigerants will result in improper operation and possible 
damage to the refrigeration system.
Line Set Size and Refrigerant Charge
Hoshizaki 
Icemaker
Hoshizaki 
Remote 
Condenser 
Unit
Line Set 
Up to 66 Feet (20 m)
Line Set 
Greater than 66 Feet (20 m)
Maximum 100 Feet (30.5 m)
Liquid 
Line
Discharge 
Line 
Charge 
Adjustment
Liquid 
Line
Discharge 
Line 
Charge Adjustment 
(R-404A)
KML-631MRH
URC-9F
3/8" 
OD
1/2" OD
Not 
Applicable
3/8" 
OD
1/2" OD
Add 0.4 oz. for each 
foot over 66 feet 
(40 g for each meter 
over 20 m). Write 
new total charge on 
icemaker's rating 
label.