5.44   
Water Path Leakage Test 
 
In the event water is present in bottom of the appliance, or a leak is 
suspected; the following procedure will help in locating the source of the 
leak. 
 
Caution! 
Heaters can be hot during this test and hot water may escape from the 
system. 
 
1.  Fill the Water reservoir completely 
2.  Place the appliance into the Service Mode with the Selector Knob in 
the Programming position. Refer to Section 6 - Fault Diagnosis for 
further information on service mode access. 
3.  Press and hold all three coffee buttons - check for signs of leakage 
(dripping, squirting etc...) 
4.  Release the three coffee buttons to end the test 
 
If steps 1-4 do not disclose any leaks - continue as follows. 
 
5.  Fill the Water reservoir completely 
6.  Place the appliance into the Service Mode 
7.  Quickly turn the selector knob to the “Operation” position 
8.  Press and hold all three coffee buttons for 30 seconds 
9.  Quickly turn the selector knob to the “Programming” position 
10. Press and hold all three coffee buttons - check for signs of leakage 
(dripping, squirting etc...) 
11. Release the three coffee buttons to end the test 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 