Technical Information 
 
CVA615 Coffee System 
 
5.45   
Water Path Connections - Opening 
 
Danger! 
Risk of burning or scalding! 
Components may be hot. 
Pressurized steam may exist in the system. 
Before any service work is performed, allow time to cool. 
 
Refer to Figure 5-51 – Water Path Connection. 
 
1.  Remove the retaining spring (Item 1). 
2.  Pull out the hose from the connector. 
3.  Remove the sealing rings (Item 2). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1 Retaining 
Spring 
2 Sealing 
Rings 
3 Pressed-on 
Ring 
Figure 5-51: 
Water Path Connection 
 
 
5.46   
Water Path Connections - Closing 
 
1.  Check the sealing rings for damage and replace as necessary. 
2.  Fit the sealing rings on the hose. 
3.  Insert the hose in the connector. 
4.  Fit the retaining spring behind the pressed-on ring. 
5.  As a check, pull on the hose. It should not be possible to pull the hose 
out of the connector. 
 
 
 
 
 