BEA 10MATRIX Manual Do Utilizador

Página de 12
BACK VIEW
     Main
Connector
 (86CP11)
MATRIX
USER’S GUIDE
DIGITAL INDUCTIVE LOOP SENSORS
75.1046.04   EN  20080505 
 
 
            
 
 
Page 1 of 5
3   Precautions
Shut off all power before attempting any wiring procedures.
Maintain a clean & safe environment when working in public areas.
Constantly be aware of pedestrian traffic around the door area.
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
ESD:  Circuit boards are vulnerable to damage by electrostatic discharge.  Before handling any board ensure you dissipate your body’s charge.
Always check placement of all wiring before powering up to insure that moving door parts will not catch any wires and cause damage to equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10 / A156.19) upon completion of installation.
DO NOT attempt any internal repair of the sensor. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disas-
sembly or repair:
1.  May jeopardize personal safety and may expose one to the risk of electrical shock.
2.  May adversely affect the safe and reliable performance of the product will result in a voided product warranty.
1   Description
The MATRIX (10MATRIX) Digital Inductive Loop Detector is the ideal solution for parking barrier control, motorized gates and doors, vehicle 
access control and industrial control systems.  The MATRIX is a high performance single or dual-channel vehicle detector packaged in a 
compact housing.  The connection is made with a standard industrial 11-pin round connector.  The six versions listed below include single or 
dual-channel, and 3 possible power supplies:
10MATRIXS110   : Single loop detector with 110 to 120 V AC power supply.
10MATRIXS220   : Single loop detector with 220 to 240 V AC power supply.
10MATRIXS1224 : Single loop detector with 12 to 24 V AC/DC power supply.
10MATRIXD110   : Dual loop detector with 110 to 120 V AC power supply.
10MATRIXD220   : Dual loop detector with 220 to 240 V AC power supply.
10MATRIXD1224 : Dual loop detector with 12 to 24 V AC/DC power supply.
“The Peak Of Detection” 
Power LED
Dip Switches
Detection State LED
Presence Time
  Adjustment
Potentiometer
Sensitivity Adjustment
        Potentiometer
      (Dual Loop Only)
Detection State LED
   (Dual Loop Only)
Sensitivity Adjustment
        Potentiometer
2   Specifications
TERMINOLOGY
SPECIFICATION
TERMINOLOGY
SPECIFICATION
TECHNOLOGY
Inductive Loop
POWER FREQUENCY
48 to 62 Hz
TUNING
Automatic
POWER CONSUMPTION
< 2.5 W
DETECTION MODE
Presence
TEMPERATURE RANGE
-22ºF to 158ºF (-30ºC to 70ºC)
PRESENCE TIME
1 min to infinity with 250 steps
DEGREE OF PROTECTION
IP40
PULSE TIME OUTPUT
100 ms or 500 ms
WEIGHT
7 oz. (<200g)
LED INDICATORS
Power:  Green
Loop Status 1:  Red
Loops Status 2:  Red
PROTECTIONS
Loop Insulation Transformer
Zener Diodes
Gas Discharge Clamping
FREQUENCY RANGE
20 kHz to 130 kHz
INDUCTANCE RANGE
20 H to 1000 H
FREQUENCY STEPS
Single Loop:  4
Double Loop:  2 (for each loop)
DIMENSIONS
3.0 in (H) x 1.5 in (W) x 3.0 in (D)
(76mm x 38mm x 76mm)
SENSITIVITY (ΔL / L)
0.005% to 0.5% with 250 steps
CONNECTION
86CP11 (Standard 11-Pin Round)
REACTION TIME
Single Loop:  25ms  
Double Loop: 50ms (ea. channel)
2 OUTPUT RELAYS (free po-
tential change-over contact)
Max Contact Voltage:  230 VAC
Max Contact Current:  5A (res.)
SETUP TIME AFTER CONFIGURATION
2 s max by channel
SETUP TIME AT POWER ON
8 s max by channel
POWER SUPPLY
(depending on model)
12-24 AC/DC + 10%
230 VAC  + 10%
115 VAC + 10%
PRODUCT COMPLIANCE
R&TTE:  1999/5/EC
EMC:  89/336/EEC
FCC:  47 CFR 15
IC:  RSS-210 ISSUE 5
FCC ID#: G9B-MATRIX     IC ID#: 4680A-MATRIX