Página de 364
U P D A T I N G     S O F T W A R E   –   S T E P   3  
Step 
3. Loading the MNS-6K software 
Load the new version of  the MNS-6K image….. 
T this stage, the Magnum MNS-6K software has been downloaded from the 
GarrettCom site, and the configuration saved. The Magnum-6K switch is now ready to 
upload the new MNS-6K software image.  
Before loading the MNS-6K software 
It will be necessary for the Magnum 6K switch to be reset or re-booted after the new MNS-6K 
software is loaded. Since this may cause a network outage, software upgrades should be 
performed when it is tolerable for the outage and the appropriate users are informed of this 
outage.  
Alternately, if the S-Ring technology is used, the outage will not be noticeable and the switch will 
be re-inserted in the S-Ring after the upgrade is performed. It is however a good practice to 
inform the affected people of a possible outage. 
Accessing the switch 
Continue to use the access method defined in steps 1 and 2. 
The command used for upgrade is  
Syntax    upgrade mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>] 
Where  
mode is the mode by which the software will be accessed for upload – serial, ftp or tftp 
ipaddress is the IP address of the ftp or tftp server (only used when mode = ftp or tftp) 
file=name is the name of the MNS-6K software file to be used for upgrade. This file was 
downloaded from the GarrettCom site (as described in steps 1 and 2). 