Tektronix 2200 Manual Do Utilizador

Página de 188
2-65
Cable Connections
Connector Installation 
The connector that plugs into the Remote Aux Panel has screw clamps to 
hold the wires. Paying attention to polarity (see 
into the appropriate holes and screw down the clamps. If there is another 
control panel, the cable to the next panel must also be inserted into this 
connector. The D connector on that cable must be cut off, and the wires for 
the next panel must be stripped and inserted into the same holes before the 
screws are tightened. Make sure the polarity is correct. Refer to 
If you are building your own cable, use a shielded twisted-pair such as 
Belden 8451 and refer to 
 
Table 2-5. Cable Polarity
Panel Connector
D-Connector
Factory Supplied Cable
+ (Plus)
3 and 7
Red
– (Minus)
2 and 8
Black
Shield
9
Shield
Figure 2-32.  Remote Aux Panels Connection 
KEEP SHIELD CONNECTION AS SHORT AS POSSIBLE
From Switcher or
Previous Panel
To Next Panel
(if any)
To Pin 9 of
D Connector
(SHIELD)
To Pins 2 and 8 of
D Connector (–)
To Pins 3 and 7 of
D Connector (+)