Calibrate the Ribbon and Media Sensors Manually
Use the calibration procedure in this section when necessary to calibrate the printer based on
the media and ribbon that you are currently using. Manual calibration is recommended
whenever you are using pre-printed labels (or label backing) or if the printer will not correctly
auto calibrate.
the media and ribbon that you are currently using. Manual calibration is recommended
whenever you are using pre-printed labels (or label backing) or if the printer will not correctly
auto calibrate.
• For issues that may be resolved by sensor calibration, see
.
• For a summary of the options for initiating calibration, see
To perform sensor calibration, complete these steps:
1.
With the printer in the Ready state, initiate media and ribbon calibration through the
printer’s display:
printer’s display:
a.
Navigate to the following parameter. See
for
information about using the control panel.
b.
Press RIGHT SELECT to select
START
.
The printer does the following:
•
The STATUS light and SUPPLIES light flash yellow once.
•
The PAUSE light blinks yellow.
•
The control panel displays:
LOAD BACKING
Important •
Follow the calibration procedure exactly as presented. All of the steps must be
performed even if only one of the sensors requires adjustment. You may press and hold
CANCEL
at any step in this procedure to cancel the process.