Campbell Hausfeld SDM-SIO4 Manual Do Utilizador

Página de 72
SDM-SIO4 User Guide
5-24
;end of IF
6:  End (P95)
*Table 2 Program
  02: 0.0000    Execution Interval (seconds)
*Table 3 Subroutines
;interrupt routine for control port 8
1:  Beginning of Subroutine (P85)
 1: 98       Subroutine 98
;get voltages into locations 3 and 4
2:  SDM-SIO4 (P113)
 1: 1        Reps
 2: 0        Address
 3: 1        Send/Receive Port 1
 4: 4        Command
 5: 0        1st Parameters
 6: 0        2nd Parameters
 7: 2        Values per Rep
 8: 3        Loc [ voltage1  ]
 9: 1.0      Mult
10: 0.0      Offset
;set the output flag so that readings can be stored into
;final storage.
3:  Do (P86)
 1: 10       Set Output Flag High (Flag 0)
;time stamp.
4:  Real Time (P77)
 1: 1111     Year,Day,Hour/Minute,Seconds
;instantaneous readings stored into final storage.
5:  Sample (P70)
 1: 2        Reps
 2: 3        Loc [ voltage1  ]
;end of interrupt routine.
6:  End (P95)
End Program
Where multiple ports are being used, the first instruction would
have to be command 1 to see which port has data, followed by a
second call, or calls,  to collect the data.
NOTE