Empire Comfort Systems VFDR18LB10N-1 Manual Do Utilizador

Página de 32
Page 20
23099-1-0707
VFDM(18,24,30)LB LIGHTING INSTRUCTIONS
WARNING: If you do not follow these instructions exactly, a fire or explosion may result 
causing property damage, personal injury or loss of life.
A.  This  appliance  has  a  pilot  which  must  be  lighted  by 
hand. When lighting the pilot, follow these instructions 
exactly.
B.  BEFORE LIGHTING, smell all around the appliance area 
for gas. Be sure to smell next to the floor because some 
gas is heavier than air and will settle on the floor.
  WHAT TO DO IF YOU SMELL GAS
 
•  Do not try to light any appliance
 
•  Do not touch any electrical switch; Do not use any 
phone in your building
 
•  Immediately call your gas supplier from a neighbor's 
phone. Follow the gas supplier's instructions.
 
•  If you cannot reach your gas supplier, call the fire 
department.
C.  Use only your hand to push in or turn the gas control knob. 
Never use tools. If the knob will not push in or turn by 
hand, don't try to repair it, call a qualified service tech-
nician. Force or attempted repair may result in a fire or 
explosion.
D.  Do not use this appliance if any part has been under water. 
Immediately call a qualified service technician to inspect 
the appliance and to replace any part of the control system 
and any gas control which has been under water.
FOR YOUR SAFETY READ BEFORE LIGHTING
1.  STOP! Read the safety information above on this page.
2.  Push in gas control knob slightly and turn clockwise 
 
to "OFF." Do not force.
3.  Wait ten (10) minutes to clear out any gas. Then smell for 
gas, including near the floor. If you smell gas, STOP! Follow 
"B" in the safety information above. If you do not smell gas, 
go to the next step.
4.  Find pilot - the pilot is located in 
front of the rear log.
5.  Turn  manual  gas  control  knob 
counterclockwise 
  to 
"PILOT."
6.  Push in manual gas control knob all the way and hold in. 
Repeatedly push the piezo ignitor button until pilot is lit (or 
use a match to light). Continue to hold the control knob in 
for about one (1) minute after the pilot is lit. Release knob 
and it will pop back up. Pilot should remain lit. If it goes out, 
repeat steps 2 through 6.
 
•  If knob does not pop up when released, stop and im-
mediately callyou service technician or gas supplier
 
•  If the pilot will not stay lit after several tries, turn the gas 
control knob to "OFF" and call your service technician 
or gas supplier.
7.  Three heat settings can be selected by slightly depressing the 
manual gas control knob and turning the manual gas control 
knob counterclockwise 
 to 1, 2 or 3.
8.  CAUTION! WHen the manual gas control knob has been 
turned to desired heat setting, ensure that the manual gas 
control knob is locked into that heat setting and cannot be 
turned without being depressed. If the manual gas control 
knob is in mid-position, between heat settings, incomplete 
combustion will take place, causing odor and may produce 
gas leakage or carbon monoxide.
LIGHTING INSTRUCTIONS
CONTROL KNOB INDICATOR
GAS CONTROL KNOB SHOWN IN “OFF” POSITION
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NAT)
PILOT
1.  Push in gas control knob slightly and turn clockwise 
 
to "OFF." Do not force.
TO TURN OFF GAS TO APPLIANCE