Empire Comfort Systems VFDR18LB10N-1 Manual Do Utilizador

Página de 32
Page 21
23099-1-0707
Figures 21 and  22 show a correct pilot flame pattern. The correct 
flame will be blue and will extend beyond the thermocouple. The 
flame will surround the thermocouple just below the tip. A slight 
yellow flame may occur where the pilot flame and main burner flame 
meet. Figures 23 and 24 show an incorrect pilot flame pattern. The 
incorrect pilot flame is not touching the thermocouple. This will 
cause the thermocouple to cool. When the thermocouple cools, the 
heater will shut down.
Correct Pilot Flame Pattern for VFDR
Figure 21
Correct Pilot Flame Pattern for VFDT & VFDM 
Figure 22
Incorrect Pilot Flame Pattern for VFDR
Figure 23
Incorrect Flame Pattern for VFDT & VFDM
Figure 24
If pilot flame pattern is incorrect, as shown in Figures 23 and 24
•  See Troubleshooting, page 23.
THERMOPILE
(VFDR ONLY)
PILOT
THERMOCOUPLE
(NATURAL)
THERMOCOUPLE
(LPG)
THERMOPILE
(VFDR ONLY)
PILOT
THERMOCOUPLE
(NATURAL)
THERMOCOUPLE
(LPG)
PILOT FLAME CHARACTERISTICS