Sanyo DSR - 300 Manual Do Utilizador

Página de 136
MENU-SPECIFIC SETTINGS
2
English
109
(when optional interface board is installed)
This screen displays settings relevant to the unit’s 
interfaces.
z
It will not be possible to modify settings: The screen 
displays data for confirmation purposes only.
Set a warning buzzer to sound for alarms or when the hard 
disk space reaches zero as described below.
1
Select “ON” or “OFF” for the alarm 
buzzer.
z
To sound a buzzer on the PC
Create a folder named BUZZER in the PC’s root 
directory, and save the sound file to use as the buzzer 
tone as C:\BUZZER\BUZZER.WAV.
When a PC-monitored DVR generates an alarm, the PC 
also sounds a buzzer, using the saved sound file.
2
Click [SAVE]. 
The new settings are saved.
11. RS-232C/RS-485 SET
(1)
(2)
(3)
(4)
(5)
Item
Overview
Setting
Description
(1) CONTROL
Displays the type if interface being 
used for control of the unit.
RS-232C
When RS-232C is being used.
RS-485
When RS-485 is being used.
(2) DATA SPEED
Displays the RS-232C or RS-485 
communication speed.
2400/4800/9600/
19200 (bps)
(3) STATUS INFO
Displays whether or not status 
information will be transmitted 
during RS-485 communication.
ON
Status information will be transmitted.
OFF
Status information will not be transmitted.
(4) ALARM INFO
Displays whether or not alarm 
information will be transmitted 
during RS-485 communication.
ON
Alarm information will be transmitted.
OFF
Alarm information will not be transmitted.
(5) ADDRESS
Displays the address when RS-485 
has been selected.
0 to 127
Set within the range of 0 to 127.
12. BUZZER SET
(1)
(2)
2
(3)
(4)
(5)
(6)
Item
Default setting
Description
(1) ALARM
OFF
Sounds a buzzer when an alarm is detected.
(2) DISK FULL
ON
Sounds a buzzer when the amount of data stored in each of the hard disk’s recording areas has 
reached the remaining-space warning level. (JP. 102)
(3) DISK ERROR
ON
Sounds a buzzer when a hard-disk error occurs.
(4)
LOCK 
WARNING
ON
Sounds a buzzer when an operation button not permitted for the current user level is pressed while 
the security lock is set. Specifically, the buzzer sounds twice with an interval of approximately 0.5 
seconds.
(5) KEY IN
OFF
The buzzer emits a key-operation sound each time a button is pressed.
(6) NON REC
OFF
Sounds a buzzer when recording is stopped.
e00_l8had_us_7.book  Page 109  Wednesday, March 10, 2004  2:47 PM