4   SETTING AND PROCEDURE BEFORE OPERATION 
 
4.10.4 Communication test 
This test checks whether communications is normally performed between the host 
station and a communication-target station (specified with the network number and 
station number). 
If the communication-target station is in another network, the relay network number 
and station number are displayed and the routing parameter settings can be checked. 
 
Host
1R1
1R2
Network No. 1
1R4
1R3
2N
S
1
2N
S
3
Network No. 2
2N
S
6
2N
S
4
1MR
2M
P
2
2N
S
5
3M
P
1
3N
S
3
3N
S
5
3N
S
4
3N
S
2
4N
S
5
4M
P
1
4N
S
2
Network No. 4
4N
S
6
4N
S
4
Destination
Network No. 3
4N
S
3
GX Developer
 
 
When the communication test is performed from GX Developer connected to the 2M
P
in network number 2 to the 4N
S
6 in network number 4 in the system above, the 
following screen appears. The result shows that communications between two stations 
is normal. 
 
Forward path from the host 
to the destination
Return path from the destination 
to the host
Station numbers of
relay stations.
5 is the station No. of
network No. 2 side.
1 is the station No. of
network No. 3 side.