2 - 1                                                                                                                                                             2 - 1 
MELSEC-Q
2   SYSTEM CONFIGURATION 
 
2 SYSTEM CONFIGURATION 
This introduces a system comprised of remote I/O networks. 
 
POINT 
 
(1)  Remote I/O networks and PLC to PLC networks cannot be mixed on the same 
MELSECNET/H network. Always build separate networks. 
 
(2)  Only MELSECNET/H network modules can be connected to a MELSECNET/H 
remote I/O network. They cannot be mixed with MELSECNET/10 network 
modules (AJ72LP25, A1SJ72QLP25, etc.). 
 
2.1 Single Remote I/O Networks 
2.1.1 Configuration 
(1)  Optical loop system 
Up to 64 remote I/O modules can be connected to a remote master station.  
Always set the station number of the remote master station to 0. 
 
Po
w
er s
u
pp
ly
QCPU QJ71
LP21
Station number 0
(remote master station)
Station number 1
(remote I/O station)
I/O
QJ72
LP25
I/O
Station number 2
(remote I/O station)
I/O
QJ72
LP25
I/O
Optical fiber cable
Po
w
er s
u
pp
ly
Po
w
er s
u
pp
ly
I/O
QJ72
LP25
I/O
I/O
QJ72
LP25
I/O
Po
w
er
 s
u
pp
ly
Po
w
er
 s
u
pp
ly
I/O
QJ72
LP25
I/O
Po
w
er
 s
u
pp
ly
Station number 4
(remote I/O station)
Station number 3
(remote I/O station)
Station number 64
(remote I/O station)
 
 
(2)  Coaxial cable bus system 
Up to 32 remote I/O stations can be connected to a remote master station.  
Always set the station number of the remote master station to 0. 
 
QCPU QJ71
BR11
Terminating resistor
(Sold separately)
Terminating resistor
(Sold separately)
Coaxial cable 
Station number 1
(remote I/O station)
I/O
QJ72
BR15
I/O
Station number 32
(remote I/O station)
I/O
QJ72
BR15
I/O
P
ower supply
P
ower supply
P
ower supply
Station number 0
(remote master station)
 
 
 
 
 
 