Press MENU until the SET UP 3 display appears
on the screen.
2
Press SHIFT 
v to move the flashing to TAPE END
OUT and set to –3M or END by pressing DATA
‘/’.
3
Press PAUSE/SEARCH to return to the normal
display.
SW OUT Terminal
The VCR outputs a pulse signal from the SW (switch)
OUT terminal to the camera switcher to control the
switching from camera to camera.
Specify the interval between each pulse signal on the
SET UP 4 display.  Also, set TIMING to FIELD or
FRAME depending on the specifications of the camera
switcher.
Available settings are:
• FIELD: 1, 2, 3, 4, 5, 10, 30, or 60 fields
• FRAME: 1, 2, 3, 4, 5, 10, 30, or 60 frames
1
Press MENU until the SET UP 4 display appears
on the screen.
01 of FIELD is flashing.
2
Set the interval by pressing DATA ‘/’ and press
SHIFT 
b.
3
Set TIMING to FIELD or FRAME by pressing
DATA ‘/’.
4
When the TAPE switch is set to T-120:
Set 6H (6-hour mode) to Y (yes) or N (no) by
pressing DATA ‘/’.
Y (yes): a signal is output in the 6-hour mode
N (no): a signal is not output in the 6-hour mode
When the TAPE switch is set to T-160:
Set 8H (8-hour mode) to Y (yes) or N (no) by
pressing DATA ‘/’.
Y (yes): a signal is output in the 8-hour mode
N (no): a signal is not output in the 8-hour mode
5
When you have completed the settings, press
PAUSE/SEARCH to return to the normal display.
SW OUT terminal
COM terminal
Terminals
              <SET  UP  3>
ALARM  MODE
ALARM  SPEED
ALARM  DURATION
EXT  TIME  ADJ.
TAPE  IN  MODE
TAPE  END  MODE
TAPE  END  OUT
CLOG  DETECT.
SERIES REC
Y1
6H
20S
01:00
STOP
REW
-3M
Y
N
              <SET  UP  4>
SW  OUT
      FIELD
      TIMING
      6H
<USED TIME>
01
FIELD
Y
              <SET  UP  4>
SW  OUT
      FIELD
      TIMING
      6H
<USED TIME>
04
FIELD
Y
              <SET  UP  4>
SW  OUT
      FRAME
      TIMING
      6H
<USED TIME>
04
FRAME
Y