6 - 109 
6. APPLICATION FUNCTIONS 
 
Parameter 
No. 
Abbreviation Name 
Initial 
value 
Units
Setting 
range 
Function 
02B4 
MKNL1 
Latch data range 
lower limit 1 
(lower) 
0000h  
0000h 
to 
FFFFh
Specify the range (lower limit) of data to be latched at detection 
of the mark detection signal of mark detection signal number 
specification 1. (Note1), (Note 2) 
02B5 
MKNH1 
Latch data range 
lower limit 1 
(upper) 
0000h  
0000h 
to 
FFFFh
02B6 
MKXL1 
Latch data range 
upper limit 1 
(lower) 
0000h  
0000h 
to 
FFFFh
Specify the range (upper limit) of data to be latched at detection 
of the mark detection signal of mark detection signal number 
specification 1. (Note1), (Note 2) 
02B7 
MKXH1 
Latch data range 
upper limit 1 
(upper) 
0000h  
0000h 
to 
FFFFh
02B8 
MKNL2 
Latch data range 
lower limit 2 
(lower) 
0000h  
0000h 
to 
FFFFh
Same as latch data range lower limit 1. 
02B9 
MKNH2 
Latch data range 
lower limit 2 
(upper) 
0000h  
0000h 
to 
FFFFh
02BA 
MKXL2 
Latch data range 
upper limit 2 
(lower) 
0000h  
0000h 
to 
FFFFh
Same as latch data range upper limit 1. 
02BB 
MKXH2 
Latch data range 
upper limit 2 
(upper) 
0000h  
0000h 
to 
FFFFh
Note 1. When changed while system is running, changes are enabled when a mark detection settings enable command is input. 
2. The set units are regarded as command units, or pulse units (the unit set in mark detection data type (parameter No.02B1)). 
 
 
API LIBRARY  
• Use the sscChange2Parameter/sscCheck2Parameter functions to set/get 
mark detection.