Справочник Пользователя для Mitsubishi Electronics MR-MC210

Скачать
Страница из 658
 
 
 
App. - 37 
APPENDIX 
 
(b) Control parameter 
 
Parameter 
No. 
Abbreviation Name Initial 
value 
Units
Setting 
range 
Function 
0203 *AXALC 
Axis 
No. 
assignment 
0000h  0000h 
to 
011Fh
0
Servo amplifier axis No.
Set the servo amplifier axis No. to
be assigned to the axis Nos. on the
position board. (Note 1, 2 and 3)
00h: No axis No. assignment
01h to 14h: Axis No.
Example) 0Ah: Axis No. 10
Servo amplifier line No.
Set the servo amplifier line No. to be
assigned to the axis Nos. on the
position board.
0 to 1: Line No.-1
Note 1. An axis No. out of the valid range causes the system setting error (alarm No. 38, detail 03). 
         2. Regardless of the control axis setting (parameter No.0200), set the axis No. so that the axis No. assignment is not duplicated. 
(Except for 00: No axis No. assignment) Duplicated axis Nos. cause the system setting error (alarm No. 38, detail 04). 
         3. When Control is set in the control axis setting (parameter No.0200), always set the axis Nos. (1 to 16). When 0 is set, system 
setting error (alarm No. 38, detail 02) will occur.