Справочник Пользователя для Mitsubishi Electronics MR-MC210

Скачать
Страница из 658
 
 
 
App. - 38 
APPENDIX 
 
App. 5.10 Sensor input option setting 
External signal (sensor) is connected by setting sensor input options (parameter No.0219). 
 
Parameter 
No. 
Abbreviation Name  Initial 
Value 
Units
Setting 
range 
Function 
0219 *SOP 
Sensor 
input 
options 
0000h 
 
0000h to
0304h 
0
Sensor input system
Set the input system of the sensor
(LSP, LSN, DOG).
0: Not use
1: Driver input
2: Digital input
3: Not connected (does not detect
    LSP, LSN, DOG)
4: Dual port memory input
Limit switch signal selection
Set valid / invalid of limit switch.
0: LSP/LSN are valid
1: LSP is valid, LSN is invalid
2: LSP is invalid, LSN is valid
3: LSP/LSN are invalid
0
 
021A *SLSP 
Sensor 
signal (LSP) 
connection 
specification 
0000h 
 
0000 to 
3FF1h
Digital input assignment
Set valid/invalid for the digital input
assignment where LSP is
connected.
0: Not assigned
1: Assigned
Digital input number assignment
Set the digital input number where
the LSP is connected.
000h to 3FFh: DI_000 to DI_3FF
 
021B *SLSN 
Sensor 
signal (LSN) 
connection 
specification 
0000h 
 
0000 to 
3FF1h
Digital input assignment
Set valid/invalid for the digital input
assignment where LSN is
connected.
0: Not assigned
1: Assigned
Digital input number assignment
Set the digital input number where
LSN is connected.
000h to 3FFh: DI_000 to DI_3FF
 
021C *SDOG 
Sensor 
signal (DOG) 
connection 
specification 
0000h 
 
0000 to 
3FF1h
Digital input assignment
Set valid/invalid for the digital input
assignment where DOG is
connected.
0: Not assigned
1: Assigned
Digital input number assignment
Set the digital input number where
DOG is connected.
000h to 3FFh: DI_000 to DI_3FF