Справочник Пользователя для Mitsubishi Electronics MR-MC241

Скачать
Страница из 658
 
 
6 - 121 
6. APPLICATION FUNCTIONS 
 
6.31 Continuous operation to torque control 
6.31.1 Summary 
Continuous operation to torque control is a control method that achieves torque control during positioning 
control without stopping. 
To perform continuous operation to torque control, the servo amplifier control mode must be switched to 
"continuous operation to torque control mode". By setting the "continuous operation to torque control 
specification" auxiliary command in the point table to "continuous operation to torque control valid", torque 
control is performed from the position (command position or current feedback position) set in the switch 
conditions without stopping operation. Continuous operation to torque control is completed based on the 
continuous operation to torque control data, then returned to position control. 
Also, when the continuous operation to torque control operation condition "start switch to continuous operation 
to torque control condition" is set to "manual switch", a switch to continuous operation to torque control can be 
made at any given time. 
The continuous operation to torque control data becomes valid at the start of operation for the points set to 
continuous operation to torque control valid (hereinafter referred to as continuous operation to torque control 
points). 
 
 
POINT 
 
• Continuous operation to torque control data that is changed during the 
operation of a continuous operation to torque control point becomes valid at 
the operation of the next continuous operation to torque control point.