Справочник Пользователя для Mitsubishi Electronics MR-MC241

Скачать
Страница из 658
 
 
6 - 123 
6. APPLICATION FUNCTIONS 
 
6.31.2 Interface 
Set the following data when using continuous operation to torque control. 
 
(1) Parameter 
(a) Servo parameter 
 
Parameter 
No. 
Abbreviation Name 
Initial 
value 
Units
Setting 
range 
Function 
110D *POL 
Rotation 
direction 
selection/travel 
direction 
selection 
 
0 to 1 
Select the rotation direction or travel direction for the command 
input pulse. 
1142 TFBGN 
Torque 
feedback loop 
gain 
18000  rad/s 0 to 18000 Set the torque feedback gain for continuous operation to torque 
control. 
By setting a smaller value, the contact load at continuous 
operation to torque control can be reduced. 
When setting value is less than 6[rad/s], a setting value of 
6[rad/s] is set. 
 
(b) Control parameter 
 
Parameter 
No. 
Abbreviation Name 
Initial 
value 
Units
Setting 
range 
Function 
0205 ITM2 
Interrupt 
condition 2 
0000h   0000h 
to 
FFFFh
Set interrupt condition 2. 
0222 SPLL 
Speed 
limit 
value (lower) 
0BB8h Speed 
units
0000h to 
FFFFh
Set the value for the moving speed limit. 
0223 SPLH 
Speed 
limit 
value (upper) 
0000h 0000h 
to 
7FFFh
 
 
API LIBRARY  
• Use the sscChange2Parameter/sscCheck2Parameter functions to set/get 
parameters.