Справочник Пользователя для Mitsubishi Electronics MR-MC241

Скачать
Страница из 658
 
 
9 - 16 
9. INTERFACE MODE 
 
9.5.4 Torque control mode 
Torque control mode is where torque commands (torque in units of 0.1%) generated by the user program of 
the host controller can be sent to the servo amplifier. The torque command buffer is made up of torque 
command data × a maximum of 1 buffer. 
Refer to Section 9.5.6 for the update method of the buffer. 
 
The relationship between the torque command and the direction of the output torque of the servo motor differs 
depending on the settings of rotation direction selection/movement direction selection (servo parameter 
No.110D) and function selection C-B (servo parameter No.119C). The torque command during torque control 
mode is restricted by the torque control speed limit value. 
The meanings of the signs for the following data that can referred to by the monitor during torque control mode 
differ from other control modes. 
 
• Servo information (2) 
 
Monitor No. 
Content 
Units 
020A 
Electrical current command 
0.1% 
020B 
Electrical current feedback 
0.1% 
 
The meanings of the signs for electrical current command (monitor No.020A) and electrical current feedback 
(monitor No.020B) during torque control mode are as follows. 
 
Parameter No. 
Command direction 
Motor revolution 
direction 
Electrical current command/electrical current feedback sign 
Position control 
Speed control 
Torque control 
Positive CCW 
(positive) Positive 
Positive 
Positive 
Negative CW 
(negative) Negative 
Negative 
Negative 
Positive CW 
(negative) Negative  Negative 
Positive 
Negative CCW 
(positive)  Positive 
Positive 
Negative 
 
POINT 
 
• If a value outside of the range is input to the torque command buffer, 
command data error (operation alarm A7, detail No.02) occurs. The torque 
command value becomes the value before the change. 
• When an alarm occurs, conduct a deceleration stop by the user program.
 
 
 
Zero speed (ZSP)
Torque command data
0
10
20
30
30.0%
Torque
300 to 0
300
30 to 300
0