Справочник Пользователя для Mitsubishi Electronics MR-MC241

Скачать
Страница из 658
 
 
1 - 22 
1. SUMMARY 
 
1.6 SSCNET  cables 
Connect the position board and servo amplifiers, or servo amplifier and servo amplifier by SSCNET  cable. 
When using MR-MC210/MR-MC240, the SSCNET  cable for connecting servo amplifiers can be used for one 
line only. When using MR-MC211/MR-MC241, the SSCNET  cable for connecting servo amplifiers can be 
used for up to two lines (use 1CH and 2CH). Up to 32 servo amplifiers can be connected. 
 
(1) SSCNET  cable specifications 
 
Model name 
Cable length [m(ft.)]
Description 
MR-J3BUS M 
MR-J3BUS015M 0.15 
(0.49) 
• Position board 
 
Servo amplifier 
• Servo amplifier
   
Servo amplifier 
MR-J3BUS03M 0.3 
(0.98) 
MR-J3BUS05M 0.5 
(1.64) 
MR-J3BUS1M 1 
(3.28) 
MR-J3BUS3M 3 
(9.84) 
MR-J3BUS M-A 
MR-J3BUS5M-A 5 
(16.40) 
MR-J3BUS10M-A 10 
(32.81) 
MR-J3BUS20M-A 20 
(65.62) 
MR-J3BUS M-B 
MR-J3BUS30M-B 30 
(98.43) 
MR-J3BUS40M-B 40 
(131.23) 
MR-J3BUS50M-B 50 
(164.04) 
 
(2) Connection between the position board and servo amplifiers 
Connect the SSCNET  cables to the following connectors. 
Refer to Section 3.2.1 for the connection and disconnection of SSCNET  cable. 
 
1CH
2CH
(Note)
Servo amplifier
Servo amplifier
Servo amplifier
Servo amplifier
CN1A
CN1B
CN1A
CN1B
CN1A
CN1B
CN1A
CN1B
Cap
Cap
Note. It cannot communicate if the connection of
CN1A and CN1B is mistaken.
SSCNET    cable length
MR-J3BUS   M use
1)   3m(9.84ft.)
MR-J3BUS   M-A use
1)   20m(65.62ft.)
MR-J3BUS   M-B use
1)   50m(164.04ft.)
Attach a cap to
connectors of
channel not being
used.
1)
1)
1)
1)
Position board
(Note) MR-MC211/
                  MR-MC241 only
SSCNET /H Line 2