Справочник Пользователя для Mitsubishi Electronics MR-MC241

Скачать
Страница из 658
 
 
14 - 2 
14. EMC AND LOW VOLTAGE DIRECTIVES 
 
14.1.1 Standards relevant to the EMC directive 
For all test items, the test has been done with a position board installed in a computer that is compatible to CE 
mark. 
The test does not cover USB because only the test tool "MRZJW3-MC2-UTL" (sold separately) uses it. 
 
The standards relevant to the EMC Directive are listed in table below. 
 
Certification 
Test item 
Test details 
Standard value 
EN61000-6-4:2007+A1:2011 
CISPR16-2-3, CISPR22 
Radiated emission 
(Note 1) 
Radio waves from the product 
are measured. 
30M-230MHz QP (Note 2) : 40dBµV/m 
(10m (32.81ft.) in measurement range) 
230M-1000MHz QP: 47dBµV/m 
(10m (32.81ft.) in measurement range) 
1GHz-2GHz QP: 76dBµV/m 
(3m (9.84ft.) in measurement range) 
AV: 56dBµV/m 
(3m (9.84ft.) in measurement range) 
CISPR16-2-1 
CISPR16-1-2 
Conducted emission 
Noise from the product to the 
power line is measured. 
AC power line 
0.15M-0.5MHz QP : 
79dBµV
AV (Note 3) : 66dBµV
0.5M-30MHz QP : 
73dBµV
AV : 60dBµV
EN61000-6-2:2005 
EN61000-4-2 
Electrostatic discharge 
immunity 
Immunity test in which 
electrostatic discharge is 
applied to the product. 
8kV: 10 times at 1 second interval, 
Air discharge 
4kV: 10 times at 1 second interval, 
Contact discharge 
EN61000-4-3 
Radiated immunity 
(Note 1) 
Immunity test in which electric 
fields are radiated to the 
product. 
80%AM modulation @1kHz, 
80-1000MHz  10V/m, 
1400M-2000MHz  3V/m, 
2000M-2700MHz  1V/m 
EN61000-4-4 
Electrical fast transient/ 
burst (EFT/B) immunity 
Immunity test in which burst 
noise is applied to the power 
cable and signal line. 
AC power line 
DC power line 
I/O, communication line 
: ±2kV/5kHz 
: ±2kV/5kHz 
: ±1kV/5kHz 
EN61000-4-5 
Surge immunity 
Immunity test in which surge is 
applied to the power line and 
signal line. 
AC power line 
Common mode: ±2.0kV 
Differential mode: ±1.0kV 
DC power line 
Common mode: ±0.5kV 
Differential mode: ±0.5kV 
I/O, communication line 
Common mode: ±1kV 
EN61000-4-6 
Conducted immunity 
Immunity test in which high 
frequency noise is applied to the 
power line and signal line. 
0.15-80MHz, 
80%AM modulation @1kHz, 10Vrms 
EN61000-4-11 
Voltage dip and short 
interruptions immunity 
Immunity test in which short 
interruptions are applied to the 
power supply voltage. 
0% of rated voltage, 1cycle 
Start at zero cross 
0% of rated voltage, 250/300cycle 
(50Hz/60Hz) 
40% of rated voltage, 10/12cycle 
(50Hz/60Hz) 
70% of rated voltage, 25/30cycle 
(50Hz/60Hz) 
Note 1. This product is an open type device (a device designed to be housed inside other equipment) and must be installed inside a 
conductive control panel. The corresponding test has been done with the programmable controller installed inside a control panel. 
2. QP: Quasi-peak value 