Chapter 3
Installing the Chassis
Connecting Power
3-12
Cisco Metro 1500 Series Hardware Installation Guide
78-10588-03
Figure 3-5
Rear Panel of the PSM (US Version)
Caution
Do not use damaged terminal blocks. Immediately replace damaged
or defective terminal blocks
or defective terminal blocks
Step 3
Take a medium screwdriver and push it into the rectangular hole of the terminal
block. (See Figure 3-6.) At the same time, slide the insulation-free end of the wire
into the respective rectangular hole at the bottom of the power clamp. Repeat this
step for the other wires.
block. (See Figure 3-6.) At the same time, slide the insulation-free end of the wire
into the respective rectangular hole at the bottom of the power clamp. Repeat this
step for the other wires.
Instructions for
power supply
Fan module
Fuse 2
Fuse 1
March 1999
For continued protection against risk of fire replace
only with same type and ratings of fuse.
For proper selection of power supply cord refer to
instruction manual.
only with same type and ratings of fuse.
For proper selection of power supply cord refer to
instruction manual.
Always remove both poewr cords when
disconnecting from a power source.
disconnecting from a power source.
Voltage:
Power Consumption
Fuse: 2
Fuse: 2
115/230 V 50/60 Hz
Max. Current: 2.5 A
max. 100 W
x T 2,5 A / 250 V
Made in Germany
Always remove both
power cords when dis-
connecting from power
source !
power cords when dis-
connecting from power
source !
!
Terminal blocks
Fuse
holders
Power 2
Power 1
50327