Справочник Пользователя для HP (Hewlett-Packard) 4.1.X

Скачать
Страница из 307
Troubleshooting Web Tools
264
Web Tools Limitations
This section provides information on limitations of Web Tools.
Core Switch 2/64 in Web Tools
Listed below are the known limitations in Web Tools, relating to the Core Switch 
2/64:
For the Core Switch 2/64 neither CP is updated in the “Switch View” when 
switch 0 is being rebooted. The CP data displayed on this “Switch View” is 
dependent on Switch 0, and that data is not available when Switch 0 is 
rebooting. 
Workaround: Refresh or relaunch Switch View after either switch is 
rebooted.
Rarely during a failover event, independent Web Tools clients operating on 
different machines may see slight differences in the management of those 
Core Switch 2/64 switches participating in the failover event. 
Workaround: There is no workaround. 
Under some circumstances where the 1 Gb SAN or 2 Gb SAN switches may 
be experiencing high memory usage, the Core Switch 2/64 Fabric View will 
display a fixed gray background area that says “Loading Java Applet....” This 
may also occur when a switch leaves the fabric simultaneous with a network 
problem. The period of loss of network connectivity for Web Tools is varied 
for different configurations. 
Workaround: Ensure that any 1 Gb SAN or 2 Gb SAN switches are 
upgraded with the recommended code versions to work optimally with the 
Core Switch 2/64 switches. 
Occasionally, other switches that are not Core Switch 2/64 switches may 
display the port ICONs correctly, but, be missing one or more control button 
icons. 
Workaround: Close the Switch View of the 1 Gb SAN or 2 Gb SAN switch 
and reopen it.
Zoning in Web Tools
Listed below are the known limitations in Web Tools, relating to zoning.