Справочник Пользователя для HP (Hewlett-Packard) 4.1.X

Скачать
Страница из 307
Troubleshooting Web Tools
266
information will not be shown. 
Workaround: Following a switch enable or disable, wait at least 25-30 
seconds before further action.
Telnet Button and Web Tools
Listed below are the known limitations in Web Tools, relating to the Telnet button:
On a Solaris OS v8.0 system, a telnet session cannot be launched using the 
Telnet button in Web Tools if the path of the "xterm" application is not 
included in the PATH environment variable.
Workaround: This path will vary from machine to machine, so contact your 
system administrator to find out the correct path of the "xterm" application 
and include this variable in the default environment setup file.
When using the Web Tools Fabric View or Switch View to open a telnet 
session from within Netscape, the telnet session is not automatically closed 
when exiting. 
Workaround: The telnet window must be closed manually. 
Web Tools and Windows
Listed here are issues using Web Tools in a Windows environment.
There is a problem that files created by Internet Explorer 5.5 with plugin 
1.3.1_04 may grow too large and cause Web Tools to not operate properly. 
Workaround: On Windows 2000 or Windows NT, make sure to delete the 
browser temp files periodically. Note that the Temp folder may be in a 
different location. Contact your system administrator if you have problems 
locating temp internet files. In the temp internet file folder delete the TLBxxx 
files.
Intermittently, you will not see the "Lost connection to the switch" message 
on the Switch View even though the Ethernet connection has been lost. You 
may still be able to invoke various features from Switch View such as Status, 
Info, Fan Temp, Power and Beacon. This problem may be seen in the Core 
Switch 2/64, for example, when you see the Lost connection to the switch 
error for a single switch in the chassis, when a lost connection affects both 
logical switches. 
Workaround: Verify Ethernet connection to the switch by pinging the logical 
switch IP address.