Heat Mode Air Flow
During  a  call  for  heat,  solenoid  S10  turns  on  and  air  first
enters the dryer on the bottom right side of the dryer.  The air
then passes through the open inlet air damper, then passes
through the six (6) steam coils to heat the air.  Next, the air
enters the tumbler (basket) heating the load inside.  The air
then goes through the lint screen.  Once the air is filtered by
the lint screen it is forced out of the exhaust by the blower.  A
percentage of the air being exhausted gets reheated by the
heat reclaimer to be used again.  (Refer to the “Drying Cycle”
illustration  below).
Temperature Set Point/Cool Down Mode
During a cool down mode, solenoid S10 turns off and solenoid
S9  turns  on.    In  this  mode,  the  air  enters  through  the  cool
down  damper  on  top  of  the  dryer  and  enters  the  tumbler
(basket).    The  air  then  passes  through  the  lint  basket  and
gets pushed out of the exhaust by the blower wheel.  (Refer
to the “Cool Down Cycle” illustration below).
Natural Gas and Liquid Propane (L.P.)
Gas Conversion Instructions ________
Important
Conversion  must  be  performed  by  competent
technicians  in  accordance  with  local  and  state
codes.
1. Loosen the screw on the high fire valve cap that doesn’t
have the paint drop.
2. Turn the cap to the “+” to increase the pressure or to the
“-” to decrease the pressure.
3. Take the pressure reading at the outlet of the valve.
4. Tighten the screw to lock the cap once the pressure is
set to 1.25 inches of water column (W.C.) for L.P. gas.
Steam Heat System _________________
The steam dryer uses six (6) steam coils to produce a heat
input of 60 Bhp (boiler horsepower).  The dryer utilizes three
(3)  separate  dampers  to  direct  air  in  the  drying  process  or
cool down process of a cycle.
The first damper is the cool down damper located on the top
of the dryer, and is used to bring fresh, room temperature air
into the tumbler (basket).  When the dryer is in the cool down
mode or has reached its set point temperature, the damper
will  be  in  the  open  position  further  reducing  increases  in
tumbler (basket) temperature.  When there is a call for heat,
the  damper  closes,  thereby  requiring  all  of  the  air  entering
the tumbler (basket) to go through the steam coils.
An inlet air damper is located in the middle of the right hand
section of the dryer.  During a call for heat, this damper opens,
which  allows  ambient  air  into  the  dryer,  which  then  goes
through the steam coils, heating the air.  During cool down,
or  if  the  dryer  has  reached  its  set  point  temperature,  the
damper closes eliminating air from going through the steam
coils.
The heat reclaimer is used to divert a portion of the exhausted
air  and  run  it  through  the  steam  coil,  reheating  the  air.
Depending  on  the  stroke  at  which  the  heat  reclaimer  has
been  set,  the  amount  of  reclaimed  air  will  vary.    The  heat
reclaimer  is  only  opened  during  a  call  for  heat.    Once  the
dryers' set point temperature is reached or during a cool down
mode the heat reclaimer will be closed.
Steam Coil pH Level
The  normal  pH  level  for  copper  type  steam  coils  must  be
maintained  between  a  value  of  8.5  to  9.5.    For  steel  type
steam coils the pH level must be maintained between a value
of 9.5 to 10.5.  These limits are set to limit the acid attack of
the  steam  coils.
Important
Coil  failure  due  to  improper  pH  level  will  void  the
warranty.
!
!