Tilting Piston Replacement
1. Disconnect compressed air supply from the dryer.
2. Tilt,  then  level  the  dryer  to  exhaust  as  much  air  as
possible.
3. Disengage “EMERGENCY STOP” (E-Stop).  Discontinue
electrical power to the dryer.
4. Remove the six (6) screws holding the piston cover plate.
5. Label the air lines as an aid when reconnecting.
6. Loosen  the  3/8”  compression  fittings.
7. Remove the air lines.
8. Remove the 3/8” straight connector.
9. Remove the 3/8” elbow.
10. Carefully remove the E-clips from the clevis pins.
11. Remove  clevis  pins.
12. Loosen the bottom setscrew in the piston rod eye.
13. Unscrew the piston rod eye from the tilting piston.
14. To  install  new  tilting  piston,  reverse  above  procedure
(Step #12 through Step #1).
MAN5278
MAN3483
7. Remove the two (2) 1/4-20 hex head bolts that mount
the solenoid valve.  (Refer to the illustration on the top
right of page 18.)
8. Remove the three (3) 3/8” straight connectors.  (Refer to
the  illustration  on  the  top  right  of  page  18.)    Reinstall
these connectors on the new solenoid valve body.
9. Remove  the  two  (2)  3/8”  mufflers.    (Refer  to  the
illustration on the top right of page 18.)  Reinstall these
mufflers on the new solenoid valve body.
10. The left orifice (marked #12 on the tilting solenoid valve)
now must be configured for external pilot.
Note
For 1-way tilt models proceed to Step #23.
11. Remove the two (2) Phillips head screws.
12. Carefully remove the end of the valve.
Note
The  pieces  within  the  end  of  the  valve  are  small.
Handle carefully to avoid losing parts.
13. Place the solenoid plug over the pilot orifice position of
the solenoid valve end.
14. Place the O-Ring (from Step #13) into the top portion of
the solenoid valve end.
15. Place end back onto the valve removed in Step #13.
16. Replace  the  two  (2)  Phillips  head  screws  removed  in
Step #12.
17. Remove Allen plug on the left side of the orifice marked
#12 on the tilting solenoid valve.
18. Remove the pilot air’s 1/4” compression fitting.
19. Remove the pilot air’s 1/8” elbow.  Reinstall the elbow
onto the new solenoid valve body.
20. Reconnect  the  three  (3)  air  lines  removed  in  Step  #7.
Tighten/secure  compression  fittings  on  the  air  lines
loosened in Step #7.
21. Bolt  the  solenoid  valve  in  place  using  the  two  (2)
1/4-20 hex head bolts removed in Step #8.
22. Reconnect the three (3) air line compression fittings.
23. Reestablish the compressed air supply to the dryer.
24. Check for leaks.
25. Reestablish electrical power to the dryer.
26. Engage “EMERGENCY STOP” (E-Stop) disengaged in