Steam Damper Air System Connections
The dryer is manufactured with a pneumatic (piston) damper
system,  which  requires  an  external  supply  of  compressed
air.  The air connection is made to the steam damper solenoid
valve, which is located at the rear inner top area of the dryer
just in front of the electric service relay box.
Air  Requirements
There  is  no  air  requirement  for  dryers  with  the
Electromechanical  Steam  Damper  Option.
Shaded areas are state in metric equivalents
Air Connection
Air connection to system --- 1/8” N.P.T.
Air Regulation
No  air  regulator  or  filtration  is  provided  with  the  dryer.
External regulation/filtration of 80 psi (5.51 bar) must be
provided.    It  is  suggested  that  a  regulator/filter  gauge
arrangement  be  added  to  the  compressed  air  line  just
before the dryer connection.  This is necessary to ensure
that correct and clean air pressure is achieved.
Steam  Damper  System  Operation
The steam damper, as shown in the illustration below, allows
the  coil  to  stay  constantly  charged  eliminating  repeated
expansion and contraction.  When the damper is opened, the
air immediately passes through the already hot coil, providing
instant heat to start the drying process.  When the damper is
closed, ambient air is drawn directly into the basket (tumbler),
allowing a rapid cool down.
Diagram  1  shows  the  damper  in  the  heating  (open)  mode,
allowing heat into the basket (tumbler).
Diagram  2  shows  the  damper  in  the  cool  down  (closed)
mode,  pulling  ambient  air  directly  into  the  basket  (tumbler)
without  passing  through  the  coils.
NOTE:
With the dryer off or with no air supply, the steam
damper  is  in  cool  down  mode  as  shown  in
Diagram 2.