4 - 15                                                                                                                                                       4 - 15
MELSEC-GOT
4   MONITORING SPECIFICATION
(4)   Sequence program example
Always ON
FROM H0
HE3
K4M48 K1
Remote input (RX) read
command
Remote
ready flag
M59
Error
status flag
M58
MOV H0101
D100
Command data storage
TO
H0
H1E0 D100
K1
Transfers master station RWw0
SET
M157
Initial processing request flag ON
(command execution)
M57
RST
M157
Always ON
TO
H0
H163 K4M148 K1
Remote output (RY) write
Initial processing complete flag
(ON at processing complete)