4   MONITORING SPECIFICATION
(4)   Sequence program example
Always ON
Remote input (RX) read
Refer to Section 4.6.1
Command
Error
status flag
M58
Command data storage
Transfers master station
RWw0, 1
GOT request flag ON
(command execution)
M48
Reads to PLC CPU
Always ON
Remote output (RY) write
FROM H0
HE3
K4M48 K1
MOV H0203
D100
MOV H0064
D101
TO
H0
H1E0 D100
K2
SET
M148
RST
M148
FROM H0
H2E0 D200
K3
TO
H0
H163 K4M148 K1
GOT complete flag
(ON at processing complete)
Initial setting execution program