Справочник Пользователя для Intel Server Board S5500HCV S5500HCVR

Модели
S5500HCVR
Скачать
Страница из 192
Connector / Header Locations and Pin-outs 
Intel® Server Board S5520HC / S5500HCV TPS 
 
  
Revision 
1.2 
Intel order number E39529-009 
116 
Ground 
GND 
Ground is the power supply ground 
12V 
Power 
Power supply 12 V 
Fan Tach 
In 
FAN_TACH signal is connected to the BMC to monitor the fan speed  
Fan PWM 
Out 
FAN_PWM signal to control fan speed 
Table 67. SSI 6-pin Fan Header Pin-out (J1K1, J1K2, J1K4, J1K5) 
Pin Signal 
Name Type Description 
Ground 
GND 
Ground is the power supply ground 
12V 
Power 
Power supply 12 V 
Fan Tach 
In 
FAN_TACH signal is connected to the BMC to monitor the fan speed  
Fan PWM 
Out 
FAN_PWM signal to control fan speed 
Fan Presence 
In 
Indicates the fan is present 
Fan Fault LED 
Out 
Lights the fan fault LED 
 
Note
: Intel
®
 Corporation server boards support peripheral components and can contain a 
number of high-density VLSI and power delivery components that need adequate airflow to 
cool. Intel’s own chassis are designed and tested to meet the intended thermal requirements of 
these components when the fully integrated system is used together. It is the responsibility of 
the system integrator that chooses not to use Intel
®
 developed server building blocks to consult 
vendor datasheets and operating parameters to determine the amount of airflow required for 
their specific application and environmental conditions. Intel Corporation cannot be held 
responsible if components fail or the server board does not operate correctly when used outside 
any of its published operating or non-operating limits.