Справочник Пользователя для Intel Server Board S5500HCV S5500HCVR
Модели
S5500HCVR
Intel® Server Boards S5520HC and S5500HCV TPS
Jumper Blocks
Revision 1.2
Intel order number E39529-009
117
7. Jumper
Blocks
The server boards have several 3-pin jumper blocks that you can use to configure, protect, or
recover specific features of the server boards.
recover specific features of the server boards.
The following symbol identifies Pin 1 on each jumper block on the silkscreen: ▼
Figure 47. Jumper Blocks (J1E2, J1E4, J1E5, J1E6, J1H1)
Table 68. Server Board Jumpers (J1E6, J1E2, J1E4, J1E5, J1H1)
Jumper Name
Pins
System Results
1-2
These pins should have a jumper in place for normal system operation.
(Default)
(Default)
J1E6: CMOS Clear
2-3
If pins 2-3 are connected when AC power unplugged, the CMOS settings clear
in 5 seconds. Pins 2-3 should not be connected for normal system operation.
in 5 seconds. Pins 2-3 should not be connected for normal system operation.
1-2
ME Firmware Force Update Mode – Disabled (Default)
J1E2: ME Force
Update
Update
2-3
ME Firmware Force Update Mode – Enabled
1-2
These pins should have a jumper in place for normal system operation.
(Default)
(Default)
J1E4: Password Clear
2-3
To clear administrator and user passwords, power on the system with pins 2-3
connected. The administrator and user passwords clear in 5-10 seconds after
power on. Pins 2-3 should not be connected for normal system operation.
connected. The administrator and user passwords clear in 5-10 seconds after
power on. Pins 2-3 should not be connected for normal system operation.
1-2
Pins 1-2 should be connected for normal system operation. (Default)
J1E5: BIOS Recovery
2-3
The main system BIOS does not boot with pins 2-3 connected. The system only
boots from EFI-bootable recovery media with a recovery BIOS image present.
boots from EFI-bootable recovery media with a recovery BIOS image present.