Справочник Пользователя для Intel Server Board S5500HCV S5500HCVR

Модели
S5500HCVR
Скачать
Страница из 192
Intel® Server Board S5520HC / S5500HCV TPS
 
Appendix C: BMC Sensor Tables 
Revision 1.2 
   
Intel order number E39529-009 
157
Full Sensor Name 
(Sensor name in SDR) 
Sensor 
Platform 
Applicability 
Sensor Type 
Event / 
Reading 
Type 
Event Offset 
Triggers 
Contrib. To 
System 
Status 
Assert / 
De-
assert 
Readabl
 Value / 
Offsets 
Event 
Data 
Rearm 
Stand-
by 
Fan Tachometer Sensors 
(Chassis specific 
sensor names) 
30h–39h 
Chassis-
specific 
Fan 
04h 
Threshold 
01h 
[l] [c,nc] 
nc = 
Degraded 
c = Non-
fatal2 
As and 
De 
Analog R, 
T  M 
– 
 
Fan Present Sensors 
(Fan x Present) 
40h–45h 
Chassis-
specific 
Fan 
04h 
Generic 
08h 
01 - Device 
inserted 
OK 
As and 
De 
Triggered 
Offset 
Auto 
 
 
 
– 
 
 
 
 
00 - Fully 
redundant 
OK 
01 – 
Redundancy lost 
Degraded 
02 - Redundancy 
degraded 
Degraded 
03 - Non-
redundant: 
Sufficient 
resources. 
Transition from 
redundant 
Degraded 
Fan Redundancy 
1
 
(Fan Redundancy) 
46h 
Chassis-
specific 
Fan 
04h 
Generic 
0Bh 
04 - Non-
redundant: 
Sufficient 
resources. 
Transition from 
insufficient. 
Degraded 
As and 
De 
– Trig 