Справочник Пользователя для Intel Server Board S5500HCV S5500HCVR

Модели
S5500HCVR
Скачать
Страница из 192
Appendix C: BMC Sensor Tables
 
 Intel® Server Board S5520HC / S5500HCV TPS 
  
Revision 
1.2 
Intel order number E39529-009 
158 
Full Sensor Name 
(Sensor name in SDR) 
Sensor 
Platform 
Applicability 
Sensor Type 
Event / 
Reading 
Type 
Event Offset 
Triggers 
Contrib. To 
System 
Status 
Assert / 
De-
assert 
Readabl
 Value / 
Offsets 
Event 
Data 
Rearm 
Stand-
by 
05 - Non-
redundant: 
insufficient 
resources. 
Non-fatal 
06 – Non-
Redundant: 
degraded from 
fully redundant. 
Degraded 
07 - Redundant 
degraded from 
non-redundant 
Degraded 
00 - Presence 
OK 
01 - Failure 
Degraded 
02 – Predictive 
Failure 
Degraded 
03 - A/C lost 
Degraded 
Power Supply 1 Status 
(PS1 Status) 
50h 
Chassis-
specific 
Power Supply
08h 
Sensor 
Specific 
6Fh 
06 – 
Configuration 
error 
OK 
As and 
De 
– Trig 
Offset A  X 
00 - Presence 
OK 
01 - Failure 
Degraded 
02 – Predictive 
Failure 
Degraded 
03 - A/C lost 
Degraded 
Power Supply 2 Status 
(PS2 Status) 
51h 
Chassis-
specific 
Power Supply
08h 
Sensor 
Specific 
6Fh 
06 – 
Configuration 
error 
OK 
As and 
De 
– Trig 
Offset A  X 
Power Supply 1 
AC Power Input 
(PS1 Power In) 
52h 
Chassis-
specific 
Other Units 
0Bh 
Threshold 
01h 
[u] [c,nc] 
nc = 
Degraded 
c = Non-fatal 
As and 
De 
Analog R, 
T  A  X