Appendix C: BMC Sensor Tables
 
 Intel® Server Board S5520HC / S5500HCV TPS 
  
Revision 
1.2 
Intel order number E39529-009 
160 
Full Sensor Name 
(Sensor name in SDR) 
Sensor 
Platform 
Applicability 
Sensor Type 
Event / 
Reading 
Type 
Event Offset 
Triggers 
Contrib. To 
System 
Status 
Assert / 
De-
assert 
Readabl
 Value / 
Offsets 
Event 
Data 
Rearm 
Stand-
by 
Processor 1 Thermal 
Control % 
(P1 Therm Ctrl %) 
64h All 
Temperature 
01h 
Threshold 
01h 
[u] [c,nc] 
Non-fatal 
As and 
De 
Analog Trig 
Offset  A 
– 
Processor 2 Thermal 
Control % 
(P2 Therm Ctrl %) 
65h 
Dual 
processor 
only 
Temperature 
01h 
Threshold 
01h 
[u] [c,nc] 
Non-fatal 
As and 
De 
Analog Trig 
Offset  A 
– 
Processor 1 VRD Temp 
(P1 VRD Hot) 
66h All 
Temperature 
01h 
Digital 
Discrete 
05h 
01 - Limit 
exceeded 
Fatal 
As and 
De 
– Trig 
Offset 
M  – 
Processor 2 VRD Temp 
(P2 VRD Hot) 
67h 
Dual 
processor 
only 
Temperature 
01h 
Digital 
Discrete 
05h 
01 - Limit 
exceeded 
Fatal 
As and 
De 
– Trig 
Offset 
M  – 
Catastrophic Error 
(CATERR) 
68h All 
Processor 
07h 
Digital 
Discrete 
03h 
01 – State 
Asserted 
Non-fatal 
As and 
De 
– Trig 
Offset 
M  – 
CPU Missing 
(CPU Missing) 
69h All 
Processor 
07h 
Digital 
Discrete 
03h 
01 – State 
Asserted 
Fatal 
As and 
De 
– Trig 
Offset 
M  – 
IOH Thermal Trip 
(IOH Thermal Trip) 
6Ah All 
Temperature 
01h 
Digital 
Discrete 
03h 
01 – State 
Asserted 
Fatal 
As and 
De 
– Trig 
Offset 
M  – 
 
Note 1: Sensor only present on systems that have applicable redundancy (for instance, a fan or power supply).