Справочник Пользователя для Intel Server Board S5500HCV S5500HCVR
Модели
S5500HCVR
Intel® Server Boards S5520HC and S5500HCV TPS
Functional Architecture
Revision 1.2
Intel order number E39529-009
23
Table 2. Mixed Processor Configurations
Error
Severity
System Action
Processor family not
identical
identical
Halt
The BIOS detects the error condition and responds as follows:
–
–
Logs the error into the system event log (SEL).
–
Alerts the Integrated BMC about the configuration error.
–
Does not disable the processor.
–
Displays “0194: Processor 0x family mismatch detected” message in
the Error Manager.
the Error Manager.
–
Halts the system and will not boot until the fault condition is remedied.
Processor stepping
mismatch
mismatch
Pause
The BIOS detects the stepping difference and responds as follows:
–
–
Checks to see whether the steppings are compatible – typically +/-
one stepping.
one stepping.
–
If so, no error is generated (this is not an error condition).
–
Continues to boot the system successfully.
Otherwise, this is a stepping mismatch error, and the BIOS responds as
follows:
–
Displays “0193: Processor 0x stepping mismatch” message in the
Error Manager and logs it into the SEL.
Error Manager and logs it into the SEL.
–
Takes Minor Error action and continues to boot the system.
Processor cache not
identical
identical
Halt
The BIOS detects the error condition and responds as follows:
–
–
Logs the error into the SEL.
–
Alerts the Integrated BMC about the configuration error.
–
Does not disable the processor.
–
Displays “0192: Processor 0x cache size mismatch detected”
message in the Error Manager.
message in the Error Manager.
–
Halts the system and will not boot until the fault condition is remedied.
Processor frequency
(speed) not identical
(speed) not identical
Halt
The BIOS detects the error condition and responds as follows:
–
–
Adjusts all processor frequencies to the highest common frequency.
–
No error is generated – this is not an error condition.
–
Continues to boot the system successfully.
If the frequencies for all processors cannot be adjusted to be the same,
then the BIOS:
–
then the BIOS:
–
Logs the error into the SEL.
–
Displays “0197: Processor 0x family is not supported” message in the
Error Manager.
Error Manager.
–
Halts the system and will not boot until the fault condition is remedied.
Processor Intel®
QuickPath
Interconnect speeds
not identical
QuickPath
Interconnect speeds
not identical
Halt
The BIOS detects the error condition and responds as follows:
–
–
Adjusts all processor QPI frequencies to highest common frequency.
–
No error is generated – this is not an error condition
–
Continues to boot the system successfully.
If the link speeds for all QPI links cannot be adjusted to be the same, then
the BIOS:
–
the BIOS:
–
Logs the error into the SEL.
–
Displays “0195: Processor 0x Intel® QPI speed mismatch” message
in the Error Manager.
in the Error Manager.
–
Halts the system and will not boot until the fault condition is remedied.