Справочник Пользователя для Mitel 2700-1398-B1

Скачать
Страница из 211
Mitel NuPoint Messenger Technical Documentation - Release 7.0
 
Sets the maximum time, in minutes, that another user can make, give or answer a message for 
this mailbox.  When the user reaches this limit or the server detects silence, the server stops 
recording and announces that the recording is complete.  
Enter:  Minutes, from 0 to 60; 0 prevents any messages; a period (.) means no limit 
Default:  5.0 minutes 
Caller Message Length 
Sets the maximum time, in minutes, that a caller can leave a message for this mailbox.  When the 
caller reaches this limit or the server detects silence, the server stops recording and announces 
that the recording is complete. 
Enter:   Minutes, from 0 to 60; 0 prevents any messages; a period (.) means no limit. 
Default:   5.0 minutes 
Maximum Login Time 
Sets how long, in minutes, a user can remain logged in to the mailbox in a single session.  At the 
end of this time, the server automatically logs the user out. 
Enter:  Minutes, from 0 to 50; 0 or a period (.) means no limit 
Default:  
Tips & Techniques:  The average length of call sessions affects the number of ports required 
per line group. 
Maximum NP View Inactivity Timeout 
Sets how long a clent user can set the inactivity timeout within NP View.  For more information, 
see the guides for NP View administrators and users. 
Enter:  Minutes, from 1 to 59; to reset to the default, enter a period(.) 
Default:  59 minutes 
Network Queue Message Count, 
Limits how many messages a user can make or give for remote delivery.  For more information, 
see the 
NP Net Digital Networking Manual. 
Enter:  Number between 1 and 99; to reset to the default, enter a period (.) 
Default:  73 
Maximum Attachments per Message 
Limits the number of messages that the user can attach when making or giving a message. 
©Copyright 2002, Mitel Networks Corporation 
112