Справочник Пользователя для Mitsubishi Electronics QD77MS16

Скачать
Страница из 1038
 
 
10 - 10 
Chapter 10  High-Level Positioning Control 
 
10.3.3 Condition start 
In a "condition start", the "condition data" conditional judgment designated in "[Da.14] 
Parameter" is carried out for the positioning data set in "[Da.12] Start data No.". If the 
conditions have been established, the "block start data" set in "1: condition start" is 
executed. If the conditions have not been established, that "block start data" will be 
ignored, and the "block start data" of the next point will be executed.   
 
Section [2] shows a control example where the "block start data" and "positioning data" 
are set as shown in section [1].   
 
[1]  Setting examples 
 
(1)    Block start data setting example 
 
Axis 1 block 
start data 
[Da.11] 
Shape 
[Da.12] 
Start data No.
[Da.13] 
Special start 
instruction 
[Da.14] 
Parameter 
1st point 
1: Continue 
1: Condition start 
2nd point 
1: Continue 
10 
1: Condition start 
3rd point 
0: End 
50 
0: Block start 
– 
 
 
 
 
 
 
 
 
 
 
(Note): The "condition data Nos." have been set in "[Da.14] Parameter". 
 
(2)    Positioning data setting example 
 
Axis 1 positioning 
data No. 
[Da.1] 
Operation pattern 
01: Continuous positioning control 
01: Continuous positioning control 
3 00: 
Positioning 
complete 
 
 
10 
11: Continuous path control 
11 
11: Continuous path control 
12 00: 
Positioning 
complete 
 
 
50 00: 
Positioning 
complete 
 
 
 
[2]  Control examples 
The following shows the control executed when the "block start data" of the 1st 
point of axis 1 is set as shown in section [1] and started.   
 
<1>  The conditional judgment set in "condition data No. 1" is carried out before 
execution of the axis 1 "positioning data No.1". 
  Conditions established 
  Execute positioning data No. 1, 2, and 3 
 
Go to <2>. 
  Conditions not established 
  Go to <2>. 
 
<2>  The conditional judgment set in "condition data No.2" is carried out before 
execution of the axis 1 "positioning data No. 10". 
  Conditions established 
  Execute positioning data No.10, 11, and 12 
 Go to <3>. 
  Conditions not established 
 Go to <3>. 
 
<3>  Execute axis 1 "positioning data No.50" and stop the control.