Chapter 10  High-Level Positioning Control 
 
10.3.5 Simultaneous start   
In a "simultaneous start", the positioning data set in the "[Da.12] Start data No." and 
positioning data of other axes set in the "condition data" are simultaneously executed 
(commands are output with the same timing).   
(The "condition data" is designated with "[Da.14] Parameter".) 
Section [2] shows a control example where the "block start data" and "positioning data" 
are set as shown in section [1].   
 
[1]  Setting examples 
 
(1)    Block start data setting example 
 
Axis 1 block 
start data 
[Da.11] 
Shape 
[Da.12] 
Start data No.
[Da.13] 
Special start 
instruction 
[Da.14] 
Parameter
1st point 
0: End 
3: Simultaneous start 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
(Note): It is assumed that the "axis 2 positioning data" for simultaneous starting is set 
in the "condition data" designated with "[Da.14] Parameter". 
 
(2)    Positioning data setting example 
 
Axis 1 positioning 
data No. 
[Da.1] 
Operation pattern 
01: Continuous positioning control
01: Continuous positioning control
3 00: 
Positioning 
complete 
 
 
 
 
 
 
 
 
 
 
 
[2]  Control examples 
The following shows the control executed when the "block start data" of the 1st 
point of axis 1 is set as shown in section [1] and started.   
<1>  Check the axis operation status of axis 2 which is regarded as the 
simultaneously started axis. 
  Axis 2 is standing by 
  Go to <2>. 
  Axis 2 is carrying out positioning. 
  An error occurs and simultaneous 
start will not be carried out. 
<2> Simultaneously start the axis 1 "positioning data No. 1" and axis 2 
positioning data set in "condition data No. 4. 
 
[3]  Precautions 
Positioning data No. executed by simultaneously started axes is set to condition 
data ("[Da.18] Parameter 1", "[Da.19] Parameter 2"), but the setting value of start 
axis (the axis which carries out positioning start) should be "0". If the setting 
value is set to other than "0", the positioning data set in "[Da.18] Parameter 1", 
"[Da.19] Parameter 2" is given priority to be executed rather than "[Da.12] Start 
data No.". 
(For details, refer to Section 5.5 "List of condition data".)