12 - 5 
Chapter 12    Expansion Control
 
12.1.3 Setting the required data for speed-torque control 
  Required control data setting for the control mode switching   
 
The control data shown below must be set to execute the control mode switching. 
 
Setting item 
Setting 
value 
Setting details 
Buffer memory address
QD77MS2 
QD77MS4 
QD77MS16
[Cd.138] 
Control mode 
switching request 
Set "1: Switching request" after setting 
"[Cd.139] Control mode setting". 
1574+100n 4374+100n
[Cd.139]  Control mode setting 
 
Set the control mode to switch. 
  0: Position control mode 
10: Speed control mode 
20: Torque control mode 
30: Continuous operation to torque 
control mode 
1575+100n 4375+100n
n: Axis No.-1 
: Refer to Section 5.7 "List of control data" for the setting details. 
 
When "30: Continuous operation to torque control mode" is set, set the switching 
condition of the control mode to switch to the continuous operation to torque 
control mode. 
The control data shown below must be set to set the switching condition of control 
mode. 
 
Setting item 
Setting 
value 
Setting details 
Buffer memory address
QD77MS2 
QD77MS4 
QD77MS16
[Cd.153] 
Control mode auto-
shift selection 
 
Set the switching condition when 
switching to continuous operation to 
torque control mode. 
  0: No switching condition 
  1: Current feed value pass 
  2: Real current value pass 
1593+100n 4393+100n
[Cd.154] 
Control mode auto-
shift parameter 
 
Set the condition value when setting the 
control mode switching condition. 
1594+100n 
1595+100n 
4394+100n
4395+100n
n: Axis No.-1 
: Refer to Section 5.7 "List of control data" for the setting details. 
 
  Required control data setting for the speed control mode 
 
The control data shown below must be set to execute the speed control.   
 
Setting item 
Setting 
value 
Setting details 
Buffer memory address
QD77MS2 
QD77MS4 
QD77MS16
[Cd.140] 
Command speed at 
speed control mode 
 
Set the command speed at speed control 
mode. 
1576+100n 
1577+100n 
4376+100n
4377+100n
[Cd.141] 
Acceleration time at 
speed control mode 
 
Set the acceleration time at speed control 
mode. 
1578+100n 4378+100n
[Cd.142] 
Deceleration time at 
speed control mode 
 
Set the deceleration time at speed control 
mode. 
1579+100n 4379+100n
n: Axis No.-1 