Справочник Пользователя для Mitsubishi Electronics Q173DCPU

Скачать
Страница из 174
 
 
 
4 - 10 
4   AUXILIARY AND APPLIED FUNCTIONS 
 
4.2.1 Current value control 
The current value when using the ABS encoder is controlled by following functions. 
(1)   The validity of an encoder data during operation is checked. 
(a)   Checks that the amount of change of the encoder in a 3.5[ms] is within 180 
degrees at the motor axis. (An error is displayed at the abnormal.) 
 
(b)   Checks that adjustment of the encoder data and feed-back positions 
controlled with the servo amplifier. (An error is displayed at the abnormal.) 
 
(2)   The following values can be monitored by the current value history monitor of  
MT Developer. 
 
Monitor conditions 
Monitor value 
Multiple CPU system power ON/OFF 
Home position return completion 
Encoder current value, 
Servo command value, 
Monitor current value 
(a)   Current value history monitor 
Month/day/hour/minute 
The time such as at the completion of home position return and servo 
amplifier power supply ON/OFF is indicated. 
In order to indicate the time correctly, turn on SM801 (clock data read 
request) in the Motion SFC program after setting the clock data of 
special register.  
 
(b)   Encoder current value 
When using the MR-J3- B, the multiple revolution data and within-one-
revolution data read from the encoder is indicated.  
(Note) : For the encoder current value in the home position data area, the 
encoder current value when the motor is within the in-position range 
at the completion of home position return is displayed (not encoder 
value of home position). 
 
(c)   Servo command value 
The command value issued to the servo amplifier is indicated.  
 
(d)   Monitor current value 
The current value controlled in the Motion CPU is indicated. 
(Note) : A value near the feed current value is indicated. However, because 
the monitor current value and feed current value are different data, it 
is not abnormal even if a different value is indicated. 
 
(e)   Alarms 
When an error for current value restoration occurs at the servo amplifier 
power on, an error code is indicated. 
 
(3)   By setting of the "Allowable travel during power off", if the encoder data changes 
exceeding the setting range during power-off, it checks at servo amplifier power-
on. (An error is displayed at the abnormal.) 
"Allowable travel during power off" cannot be set for the Linear servo amplifier.