4   AUXILIARY AND APPLIED FUNCTIONS 
 
4.4 ROM Operation Function 
This function is used to operate based on the data in the FLASH ROM built-in Motion 
CPU module that the user programs and parameters have been stored. 
 
4.4.1 Specifications of 7-segment LED/Switches 
No. Items 
Functions 
1)  7-segment LED 
• Indicate the operation state and error information. 
2)  Rotary switch 1 (SW1) 
3)  Rotary switch 2 (SW2) 
• Set the operation mode (Normal mode, Installation 
mode and mode operated by ROM, etc.) 
• Each switch setting is 0 to F. 
STOP RUN
0
8
C
4
123
56
79
AB
DE
F
0
8
C
4
123
56
79
AB
DE
F
Q172DCPU
CN
1
1
CAUTION
2
SW
BAT
FRONT
EMI
1)
3)
2)
 
 
 
 
 
(1)   Operation mode 
"Operation mode" of the Motion CPU is set by the rotary switch setting of Motion 
CPU module at the power supply ON of the Multiple CPU system. 
The rotary switch setting, operation mode and operation mode overview are 
shown below.  
 
(a)   Rotary switch setting and operation mode 
 
Rotary switch setting 
(Note-1)
 
SW1 SW2 
Operation mode 
Any setting (Except C) 
Installation mode 
Mode operated by RAM 
Mode operated by ROM 
Any setting 
SRAM clear 
(Note-2)
 
 
(Note-1) : Do not set except the above setting. 
(Note-2) : The programs, parameters, absolute position data, and latch data in the 
SRAM built-in Motion CPU module are cleared.