Справочник Пользователя для Mitsubishi Electronics Q173DCPU

Скачать
Страница из 174
 
 
 
APP - 13 
APPENDICES 
 
APPENDIX 2 System Setting Errors 
Motion CPUs generate a system configuration error under the following conditions. 
 
Table 2.1 System Setting Errors 
Error name 
7-segment LED 
(Note-1)
 
Error code 
(Note-2)
 
Error cause 
Check 
timing 
Operation at 
error 
occurrence 
LAY ERROR 
(SL
•  The slot set in system settings is vacant or a different 
module is installed. 
AXIS No. MULTIDEF 
•  The axis No. setting overlaps in the system settings.  
•  The axis No. (function select switch) setting of servo 
amplifier overlaps in the same SSCNET  system.  
AMP No. SETTING 
•  Not a single axis is set in system settings.  
SYS.SET DATA ERR 
•  System setting data is not written. 
•  System setting data is written without relative check.  
Or it is written at the state of error occurrence.  
AXIS No. ERROR 
•  System setting data is not written. 
I/O POINTS OVER 
•  The number of actual I/O points set in system 
settings exceeds 256. 
ROM ERROR1 
•  Type of the operating system software of data written 
to ROM is different. 
ROM ERROR2 
•  Data is not written to ROM. 
ROM ERROR3 
(
•  Data size of ROM is abnormal. 
 
•  Execute the ROM writing again. 
•  Check the adjustment for the version of Motion 
CPU, MT Developer and operating system 
software. 
 
ROM ERROR4 
(
•  Data of ROM is abnormal. 
 
•  Execute the ROM writing again. 
•  Check the adjustment for the version of Motion 
CPU, MT Developer and operating system 
software. 
 
CAN'T USE SL (
•  The motion modules that cannot be used are 
installed. 
•  Use the Motion modules (Q172DLX, Q173DPX, 
Q172DEX). 
 
UNIT SET ERR 
(
"AL" flashes 
3- times 
 
"L01" display 
10014 
(Note-3) 
•  The system setting data that set the motion modules 
that cannot be used are written. 
 
•  Use the MT Developer of version corresponding 
to the Motion modules (Q172DLX, Q173DPX, 
Q172DEX). 
 
Power 
supply ON/ 
Reset 
Cannot be 
started. 
(Motion CPU 
system 
setting error) 
 
(Note-1) : ""  AL" flashes 3-times    "L01" display"" (Repetition)   Error code is not displayed. 
(Note-2) : Error code stored in self-diagnostic error (SD0) 
(Note-3) : When the error code 10014 occurs, the system setting error flag (M2041) turns ON and the error name  is displayed on the error 
list monitor of MT Developer.