Chapter 1    Product Outline
 
1.2.4 Outline for restarting 
When a stop cause has occurred during operation with position control causing the 
axis to stop, positioning to the end point of the positioning data can be restarted from 
the stopped position by using the "[Cd.6] Restart command". 
If issued during a continuous positioning or continuous path control operation, the 
restart command will cause the positioning to be re-executed using the current position 
(pointed by the positioning data No. associated with the moment when the movement 
was interrupted) as the start point. 
 
  When "[Cd.6] Restart command" is ON 
 
(1)  If the "[Md.26] Axis operation status" is stopped, positioning to the end point of 
the positioning data will be restarted from the stopped position regardless of 
the absolute system or incremental system. 
(2)  When "[Md.26] Axis operation status" is not stopped, the warning "Restart not 
possible" (warning code: 104) will be applied, and the restart command will be 
ignored. 
 
(a)    The restart operation when the axis 1 movement amount is 300 and the 
axis 2 movement amount is 600 is shown below. 
 
Start point
address
Stop position due to stop cause
Designated end 
point position
Axis 1
400
200
100
100
300
700
Axis 2
Stop position due to stop cause
Stop position
after restart
Axis 1
400
200
100
100
300
700
Axis 2
Restart
Operation during
restart
 
 
REMARK 
If the positioning start signal/external command signal   is turned ON while the 
"[Md.26] Axis operation status" is standby or stopped, positioning will be restarted 
from the start of the positioning start data regardless of the absolute system or 
incremental system. ( : When the external command signal is set to "External 
positioning start") (Same as normal positioning.) 
 
[Example for incremental system] 
(a)    The positioning start operation, which stops the positioning control while 
executing that the axis 1 movement amount is 300 and the axis 2 
movement amount is 600, is shown below. 
 
Start point
address
Stop position due to stop cause
Designated end 
point position
Axis 1
400
200
100
100
300
700
Axis 2
Stop position due to stop cause
Stop position
after restart
Axis 1
500
200
100
100
300
900
Axis 2
Positioning
start
Operation during
positioning start