Справочник Пользователя для Mitsubishi Electronics QD77MS2

Скачать
Страница из 1038
 
 
14 - 2 
Chapter 14  Common Functions
 
14.1 Outline of common functions 
"Common functions" are executed according to the user's requirements, regardless of 
the control system, etc. These common functions are executed by GX Works2 or 
sequence programs. 
 
The following table shows the functions included in the "common functions". 
 
Common function 
Details 
Means 
Sequence 
program 
GX Works2 
Parameter initialization function
This function returns the parameter stored in the 
buffer memory/internal memory and flash 
ROM/internal memory (nonvolatile) of Simple Motion 
module to the factory-set initial value. 
 
 
Execution data backup 
function 
This function writes the "execution data", currently 
being used for control, to the flash ROM/internal 
memory (nonvolatile). 
 
 
External signal selection 
function 
This function is used to select from the following 
signals when using the upper/lower limit signal, near-
point dog signal, and stop signal. 
• External input signal of QD77MS 
• External input signal of servo amplifier 
• External input signal via CPU (the buffer memory of 
QD77MS) 
 
 
External I/O signal logic 
switching function 
This function switches I/O signal logic according to 
the equipment connected to the Simple Motion 
module. 
For the system in which with b-contact, upper limit 
switch, and lower limit switch are not used, the 
parameter logic setting can be controlled without 
wiring if it is changed to a "positive logic". 
 
 
History monitor function 
This function monitors start history, error history, 
warning history, and current value history of all 
axes. 
— 
 
Amplifier-less operation 
function 
This function executes the positioning control of 
Simple Motion module without connecting to the 
servo amplifiers. 
It is used to debug the program at the start-up of the 
device or simulate the positioning operation.   
 
— 
Virtual servo amplifier function
This function executes the operation as the axis 
(virtual servo amplifier axis) that operates only 
command (instruction) virtually without servo 
amplifiers. 
 
 
Driver communication function
This function uses the "Master-slave operation 
function" of servo amplifier. The Simple Motion 
module controls the master axis and the slave axis is 
controlled by data communication between servo 
amplifiers (driver communication) without Simple 
Motion module. 
 
 
Mark detection function 
This function is used to latch any data at the input 
timing of the mark detection signal (DI1 to DI4). 
 
 
Optional data monitor function
This function is used to store the data selected by 
user up to 4 data per axis to buffer memory and 
monitor them.