Chapter 14  Common Functions
 
14.2 Parameter initialization function 
The "parameter initialization function" is used to return the setting data set in the buffer 
memory/internal memory and flash ROM/internal memory (nonvolatile) of Simple 
Motion module to their factory-set initial values. 
 
The details shown below explain about the "parameter initialization function". 
[1] Parameter initialization means 
[2] Control details 
[3] Precautions during control 
[4] Parameter initialization method 
 
[1]  Parameter initialization means 
• Initialization is executed with a sequence program. 
• Initialization is executed by GX Works2. 
 
Refer to the "Simple Motion Module Setting Tool Help" of GX Works2 for the 
execution method by GX Works2. 
 
[2]  Control details 
The following table shows the setting data initialized by the "parameter 
initialization function".   
(The data initialized are "buffer memory/internal memory" and "flash 
ROM/internal memory (nonvolatile)" setting data.)   
 
Setting data 
Basic parameters ([Pr.1] to [Pr.10]) 
Detailed parameters ([Pr.11] to [Pr.42], [Pr.80] to [Pr.90], [Pr.95]) 
OPR basic parameters ([Pr.43] to [Pr.48]) 
OPR detailed parameters ([Pr.50] to [Pr.57]) 
Expansion parameters ([Pr.91] to [Pr.94], [Pr.96], [Pr.97], [Pr.114]) 
Servo parameters ([Pr.100], PA, PB, PC, PD, PE, PS, PF, Po, PL) 
Positioning data (No.1 to 600) 
Block start data (No.7000 to 7004) 
 
[3]  Precautions during control 
(1)  Parameter initialization is only executed when the positioning control is not 
carried out (when the PLC READY signal [Y0] is OFF). 
The warning "In PLC READY" (warning code: 111) will occur if executed 
when the PLC READY signal [Y0] is ON. 
 
(2)  Writing to the flash ROM is up to 100,000 times. If writing to the flash ROM 
exceeds 100,000 times, the writing may become impossible, and the error 
"Flash ROM write error" (error code: 801) will occur. 
 
(3)  A "PLC CPU reset" or "PLC CPU power restart" must be carried out after 
the parameters are initialized. 
 
(4)  If an error occurs on the parameter set in the Simple Motion module when 
the PLC READY signal [Y0] is turned ON, the READY signal [X0] will not be 
turned ON and the control cannot be carried out.