4.4.2  Heater/Blower Kit Installation
To install the HB6000/HB6000/220/HB6024, perform the
following steps (refer to Figure 2).
4.4.2.1  Heater Assembly
1.
Open the cover.
2.
The heater bracket is designed to attach to any two
(2) adjacent studs used in retaining the window.
3.
Remove any two (2) adjacent nuts and washers on
both sides of the window.
4.
Place the heater brackets on the studs, with the heat-
ers angled away from the window, then replace and
tighten the hardware.
4.4.2.2  Blower/PCB Assembly
1.
Open the cover.
2.
On the HS1000, the blower/PCB bracket is designed
to attach to any two (2) adjacent studs used in retain-
ing the bottom plate.
3.
Remove any two adjacent nuts and washers retain-
ing the bottom plate to the mounting frame.
4.
Place the blower/PCB bracket over the studs, then
replace and tighten the hardware.
4.4.2.3  Heater/Blower Wiring
The blower is factory wired to the PCB assembly. Con-
nect the heaters to the PCB assembly as shown in the
respective wiring diagrams (Figure 4, Figure 5, or Figure
6). Supply AC line voltage (230 VAC, 120 VAC, or 24
VAC) as shown.
Figure 2.  HB6000, HB6000/220, and HB6024 Assembly