Figure 1.  HS1000 Dimension Drawing
4.1  CEILING MOUNTING (FLUSH)
To mount the enclosure to a wall/ceiling, perform the
following steps:
1.
Open the front cover by removing the four (4) 1/4-
20 “Tampruf” screws. A special socket is provided
(fits 1/4-inch square drive). The cover hinges down.
2.
Using the mounting bracket as a template, mark
and drill holes in the mounting surfaces.
3.
Attach the enclosure with the required fasteners.
4.
Route required cables through the back and/or top
of the enclosure.
5.
Mount the camera/lens to the tilt table.
6.
Make all appropriate connections (i.e., camera
power, video (coax), lens, speakers, infrared illu-
minators, heater/power kits).
7.
Position the camera and tighten the 1/4-20 fasten-
ers to secure the tilt table in place.
8.
Close the cover and check that all components clear.
Secure the cover with the four (4) 1/4-20 “Tampruf”
screws provided.