4
Pelco Manual C489M-A (1/96)
4.3  CAMERA/LENS INSTALLATION
To install the camera/lens, perform the following steps:
1.
Remove the lid by removing the eight (8) 10-32 x
1/2" socket head cap screws.
2.
Remove two (2) 6-32 x 3/8" socket head cap
screws from the rear of the PC board. This will
allow the PC board to be pivoted out of the way.
3.
Remove four (4) 8-32 x 5/8" socket head cap
screws that hold the camera sled to the enclosure.
These screws pass through the center of the isola-
tion pads.
4.
Remove the camera sled from the enclosure by
tilting the front end up and sliding the sled for-
ward and out.
5.
Attach the camera/lens assembly to the sled. The
front of the lens should not extend more than 1/8"
beyond the front of the sled. Place the nylon washer
(supplied) under the camera head and attach with
the 1/4-20 screw supplied.
6.
Replace the camera/lens/sled assembly into the en-
closure and attach it with the four (4) 8-32 x 5/8"
socket head cap screws.
7.
Replace with PC board and attach it with the two
(2) 6-32 x 3/8" socket head cap screws.
8.
Route the camera head interconnect cable through
the 3/4" conduit hole behind each camera (in the
rear plate) and attach.
9.
Replace the lid and attach with the eight (8)
10-32 x 1/2" socket head cap screws.
4.4  HS5001 HEATER INSTALLATION
1.
Follow steps one (1) through four (4) of section
4.3 to remove the camera/lens sled.
2.
Remove the “peel and stick” cover to expose the
adhesive backing on the heater pad and position
pad on bottom, front edge of sled (end of sled
closest to window).
3.
Reinstall sled and route wires from heater to
terminal block; connect wiring per Figure 2 on
page 3.
4.5  ENCLOSURE MOUNTING
Secure the enclosure to the mounting surface with suit-
able fasteners (not supplied).
5.0  CARE AND MAINTENANCE
Regularly scheduled maintenance will help prolong the
operational life and appearance of the equipment.
Clean the viewing window regularly with a soft cloth,
using a mild, non-abrasive detergent and water solu-
tion to help maintain picture clarity. (Note that clean-
ing solution must be compatible with GE Lexan with
Margard.)